Omron V780 Series User Manual page 257

Uhf rfid system reader/writer
Hide thumbs Also See for V780 Series:
Table of Contents

Advertisement

GET OPERATION INDICATOR CUSTOM CONDITIONS
 Function
This command is used to check the NORM/ERR indicator lighting colors for communications results
that are set in the Reader/Writer.
 Command Format
Byte-0
Byte-1
Transaction identi-
fier
X
X
Parameter
Register address
Word count
 Response Formats
• Normal Response
Byte-0
Byte-1
Transaction identi-
fier
X
X
Byte-9
Byte-10
Color to flash once
for normal com-
mand execution
2 bytes
Parameter
Byte count
Color to flash once
for normal com-
mand execution
Color to flash once
for command error
Color to flash once
for unstable com-
munications
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
0006 hex
The register address (B800 hex) that specifies the operation indicator custom
settings
The number of words in the operation indicator custom conditions to read (0003
hex)
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
0009 hex
Byte-11
Byte-12
Byte-13
Color to flash once
Color to flash once
for command error
for unstable com-
munications
2 bytes
2 bytes
The number of bytes in the operation indicator custom settings (06 hex)
Gives the color to flash once when V780 command processing ends nor-
mally in 4-digit hexadecimal.
0001 hex: Green
0002 hex: Red
0003 hex: Yellow
0004 hex: Blue
0004 hex: Blue
0006 hex: Magenta
0007 hex: White
FFFF hex: Do not flash.
Gives the color to flash once when V780 command processing ends in an
error in 4-digit hexadecimal.
*The colors settings are they same as for flashing once for normal command
completion, given above.
Gives the color to flash once when the results of executing communications
diagnostics indicates that communications are unstable in 4-digit hexadeci-
mal.
*The colors settings are they same as for flashing once for normal command
completion, given above.
7 Modbus/TCP Communications
Byte-5
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
03 hex
Description
Byte-5
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
03 hex
Byte-14
Description
Byte-8
Byte-9
Byte-10
Byte-11
Register address
Word count
B800 hex
0003 hex
Default setting
Byte-8
Byte
count
06 hex
0001 hex
0002 hex
0003 hex
7 - 105
7

Advertisement

Table of Contents
loading

Table of Contents