Omron V780 Series User Manual page 251

Uhf rfid system reader/writer
Hide thumbs Also See for V780 Series:
Table of Contents

Advertisement

SET TRANSMISSION TIME
 Function
This command sets the time to stop the transmission power.
 Command Format
Byte-0
Byte-1
Transaction identi-
fier
X
X
Byte-12
Byte-13
Byte
Stop time
count
04 hex
2 bytes
Parameter
Register address
Word count
Byte count
*1.
Stop time
V780-HMD68-E
TN-JP
V780-HMD-ETN
-KR/-TW/-ID/-M
Y/-SG/-MX
V780-HMD68-E
TN-CN
V780-HMD68-E
TN-IN/-EU/-RU
Continuous transmis-
sion time
V780-HMD68-E
TN-JP*1
Models other
than
V780-HMD68-E
TN-JP
*1. The stop time cannot be set to 0000 hex in models other than V780-HMD68-ETN-JP. The default is 0010 hex.
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
000B hex
Byte-14
Byte-15
Byte-16
Reserved
Always 0000 hex.
The register address (C700 hex) that specifies setting the transmission times
The number of words in the transmission time setting (0002 hex)
The number of bytes in the transmission time setting (04 hex)
Gives the maximum time to continuously output radio waves during the execution of the
communications command in 4-digit hexadecimal.
0000 hex, 000A hex to 03E8 hex
(0000 hex is ignored, or 10 to 1,000) [ms]
000A to 03E8 hex (10 to 1,000) [ms]
000A to 03E8 hex (10 to 1,000) [ms]
0064 to 03E8 hex (100 to 1,000) [ms]
Gives the maximum time to continuously output radio waves during the execution of the
communications command in 4-digit hexadecimal.
0000 hex, 000A hex to 03E8 hex
(0000 hex is ignored, or 10 to 1,000) [ms]
Always 0000 hex.
7 Modbus/TCP Communications
Byte-5
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
10 hex
Description
Byte-8
Byte-9
Byte-10
Byte-11
Register address
Word count
C700 hex
0002 hex
Default setting
0000 hex
000A hex
000A hex
0064 hex
0000 hex
---
7
7 - 99