6 Functions
Monitor Method during Operation
To check the target levels during operation, select the Operating Option on the Focus monitor View
and click the Start Button. The Reader/Writer will start measuring the target levels of the RF Tags
and update the target level display for up to eight RF Tags in realtime. To stop taking measurements,
click the Stop Button.
 Focus Monitor View
The target level will be zero for RF Tags for which communications
processing has been completed by the host device.
Precautions for Correct Use
• The RUN indicator will light cyan during operation.
• The target level graph is updated every 500 ms and displayed for a period of 60 s.
• You can use the Save Button to download up to 360 measurements (500 ms x 360 measure-
ments = 180 s, or 3 min).
6 - 56
You cannot execute a ID READ
communications command during operation.
The host device executes communications and
the target level of RF Tags for which processing
has been completed is not displayed.