Omron V780 Series User Manual page 306

Uhf rfid system reader/writer
Hide thumbs Also See for V780 Series:
Table of Contents

Advertisement

8 Browser Interface
 Saving Files
You can click the Save Button on the Transmission Power Tuning Tab Page to save the results of trans-
mission power tuning at a specified path and file name. The transmission power tuning results are
saved in a CSV file in the following format.
CSV Format
Tx level[dBm], Success rate[%], RX level[dBm]
15,
:
27,
Tuning result :, before=XX[dBm], after=YY[dBm]
Item name
Tx level[dBm]
Success rate[%]
Rx level[dBm]
Tuning result :
before=XX[dBm], after=YY[dBm]
8 - 16
<communications_success_rate>, <reception_level>
:
:
<communications_success_rate>, <reception_level>
Gives the transmission powers that were swept through
during tuning.
15 to 27
Gives the communications success rates for the RF Tags
measured for each transmission power.
0 to 100
Gives the transmission levels measured for each transmis-
sion power.
0 or -1 to -99
Gives the tuning results.
XX: Gives the transmission power that was set before tun-
ing.
YY: Gives the transmission power that was set after tuning.
(If tuning fails, the value will be -1.)
Description
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Remarks