Number
Color
and name
Green
Yellow
NORM/
ERR
Cyan
*1. This indicator flashes from startup until Run Mode or Save Mode is entered and during IP address queries
when BOOTP is enabled.
*2. "During test operation" includes Web browser interface adjustment and execution of utility functions.
Precautions for Correct Use
Refer to 9-1-1 Errors Indicated on Operation Indicators on page 9-2 for errors indicated by the
operation indicators.
3-1-2

Operation Indicators at Startup

The Reader/Writer will start when you turn ON the power supply. The RUN indicator will flash at 0.1-s
intervals while the Reader/Writer is starting.
IP address conflict detection will operate during Reader/Writer startup.
(If using the BOOTP client is enabled, detection will also operate during BOOTP server quires.)
The RUN indicator flashes green at 0.1-s intervals.
The LINK/ACT indicator does not light.
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Status
Lit for 0.2 s
Lit for 0.2 s
Lit for 0.2 s
Lit
Red
Flashing at 0.4-s
intervals
Flashing irregularly
twice
Flashing at 0.1-s
intervals
Flashing once every
3 s
Not lit
---
3 Part Names and Functions
Description
Lights once when processing a communications
command or another command from the host device
is completed normally.
Flashes once each time an unstable communication
is detected while communications diagnosis is
enabled.
Lights once when processing a communications
command or another command from the host device
ends in an error.
Lit when a major fault has occurred. (Lit when a fatal
error has occurred.)
Flashes when a minor fault has occurred. (Flashes
when a nonfatal error has occurred.)
Flashes when a minor fault has occurred. (Flashes
when a network error occurs and the IP address
becomes undetermined.)
Flashes during installation location notification.
Flashes during operation in the Focus Mode.
Not lit when the Reader/Writer is on standby.
RUN: Green
LINK/ACT: Not lit.
3