3 Part Names and Functions
Illegal Network Setting or Incorrect Operating Mode Detection during Operation
The Reader/Writer starts in Safe Mode.
The RUN indicator flashes green
at 0.4-s intervals.
The NORM/ERR indicators flash red
at 0.4-s intervals.
NORM/ERR: Red
Major Faults
If a major fault is detected, the NORM/ERR indicators will light red. This is a fatal error, so you must
replace the Reader/Writer.
If a major fault occurs during startup, the RUN indicator will flash and the Reader/Writer will start in Safe
Mode.
The RUN indicator lights green.
The NORM/ERR indicators light red.
NORM/ERR: Red
Major Fault Detection during Operation
The RUN indicator flashes green
at 0.4-s intervals.
The NORM/ERR indicators light red.
NORM/ERR: Red
3 - 10
RUN: Green
NORM/ERR: Red
NORM/ERR: Red
NORM/ERR: Red
RUN: Green
NORM/ERR: Red
NORM/ERR: Red
NORM/ERR: Red
RUN: Green
NORM/ERR: Red
NORM/ERR: Red
NORM/ERR: Red
UHF RFID System V780-series Reader/Writer User's Manual (Z389)