3-1-4

Operation Indicators for IP Address Conflict

IP address conflict detection will operate during Reader/Writer startup. The Reader/Writer conforms to
RFC 5227 IP address conflict detection.
If the Reader/Writer detects another node with the same IP address on the same network, the
NORM/ERR indicators will flash irregularly.
In this case, you must restart (i.e., cycle the power supply) the Reader/Writer to restore operation. IP
address conflict detection does not operate while the Reader/Writer is in operation.
The RUN indicator flashes green at 0.1-s intervals.
The LINK/ACT indicator does not light.
The NORM/ERR indicators flash red irregularly
(twice every second).
3-1-5

Operation Indicators When BOOTP Server Connection Fails

If using the BOOTP client is enabled, the Reader/Writer queries the BOOTP server at startup. If con-
necting to the server is not possible within a specific period of time or a suitable IP address is not avail-
able, the NORM/ERR indicators will flash irregularly.
The RUN indicator flashes green at 0.1-s intervals.
The NORM/ERR indicators flash red irregularly
(twice every second).
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
NORM/ERR: Red
NORM/ERR: Red
3 Part Names and Functions
RUN: Green
LINK/ACT: Not lit.
NORM/ERR: Red
NORM/ERR: Red
NORM/ERR: Red
RUN: Green
NORM/ERR: Red
NORM/ERR: Red
NORM/ERR: Red
3
3 - 5