7-6-7

Reader/Writer Setting Commands: Device Settings

SET OPERATION INDICATOR CUSTOM CONDITIONS
 Function
This command sets the colors of the NORM/ERR indicators during command execution.
 Command Format
Byte-0
Byte-1
Transaction identi-
fier
X
X
Byte-12
Byte-13
Byte
Color to flash once
count
for normal com-
mand execution
06 hex
2 bytes
Parameter
Register address
Word count
Byte count
Color to flash once
for normal com-
mand execution
Color to flash once
for command error
Color to flash once
for unstable com-
munications
*1. To prevent the NORM/ERR indicators from lighting at all during command execution, set all of the lighting
conditions to "Do not flash." You cannot prevent them from lighting by setting only individual conditions.
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
000D hex
Byte-14
Byte-15
Byte-16
Color to flash once
for command error
2 bytes
The register address (B800 hex) that specifies setting operation indicator custom condi-
tions
The number of words in the operation indicator custom condition settings (0003 hex)
The number of bytes in the operation indicator custom condition settings (06 hex)
Specify the color to flash once when V780 command processing ends nor-
mally in 4-digit hexadecimal.
0000 hex: Default
0001 hex: Green
0002 hex: Red
0003 hex: Yellow
0004 hex: Blue
0005 hex: Cyan
0006 hex: Magenta
0007 hex: White
*1
FFFF hex: Do not flash.
Specify the color to flash once when V780 command processing ends in an
error in 4-digit hexadecimal.
*The color settings are they same as for flashing once for normal command
completion, given above.
Specify the color to flash once when the results of executing communica-
tions diagnostics indicates that communications are unstable in 4-digit hexa-
decimal.
*The colors settings are they same as for flashing once for normal command
completion, given above.
7 Modbus/TCP Communications
Byte-5
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
10 hex
Byte-17
Byte-18
Color to flash once
for unstable com-
munications
2 bytes
Description
Byte-8
Byte-9
Byte-10
Byte-11
Register address
Word count
B800 hex
0003 hex
0000 hex
0002 hex
0003 hex