GET DEVICE NAME
Function
This command is used to check the name that is set in the Reader/Writer.
Command Format
Byte-0
Byte-1
Transaction identi-
fier
X
X
Parameter
Register address
Word count
Response Formats
• Normal Response
Byte-0
Byte-1
Transaction identi-
fier
X
X
Parameter
Byte count
Device name
• Error Response
Byte-0
Byte-1
Transaction identi-
fier
X
X
Parameter
Exception code
Execution Examples
Execution When the Reader/Writer Device Name Is Set to V780-A001
TX: 000000000006FF03B1000020
RX: 000000000043FF034056363830532D413030310000000000...00
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
0006 hex
The register address (B100 hex) that specifies the device name
The number of words in the device name (0020 hex)
Byte-2
Byte-3
Byte-4
Byte-5
Protocol identifier
Field length
0000 hex
0043 hex
The number of words in the device name that was read (40 hex)
The device name that was read is given with up to 64 bytes of ASCII characters (up
to 63 ASCII characters plus the end code (00 hex))
If there are fewer than 63 characters, the remaining bytes are filled with 00 hex.
The device name is given with ASCII characters 20 hex (space) to 7E hex (~).
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
0003 hex
For details, refer to Exception Code on page 7-7 under 7-2-3 Response Format for
Error Completion on page 7-7.
7 Modbus/TCP Communications
Byte-5
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
03 hex
Description
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
03 hex
Description
Byte-5
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
83 hex
Description
Byte-8
Byte-9
Byte-10
Byte-11
Register address
Word count
B100 hex
0020 hex
Byte-8
Byte-9
...
Byte-72
Byte
Device name
count
40 hex
64 bytes
Byte-8
Excep-
tion code
1 byte
7
7 - 63