9-2-3
WDT Errors
A WDT timer occurs when a system runaway causes the watchdog timer to time out.
If a WDT error is detected when the system runs out of control during operation, the RUN indicator will
go out and the NORM/ERR indicators will light red. There is no error code for a WDT error and no
record is recorded in the system error log.
Error name
WDT error
Refer to 9-1-1 Errors Indicated on Operation Indicators on page 9-2 and 3-1-2 Operation Indicators at
Startup on page 3-3 for information on the operation indicators when a WDT error occurs.
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Error code
A system runaway in the Reader/Writer was detected.
---
This is a fatal error, so you must either restart or replace the
Reader/Writer.
9 Troubleshooting
Description
9
9 - 7