7 Modbus/TCP Communications
RESET FOCUS
 Function
This command initializes the target level information of all the RF Tags that are being monitored by
the Reader/Writer in Focus Mode.
 Command Format
Byte-0
Byte-1
Transaction identi-
fier
X
X
Byte-12
Byte-13
Byte
Options
count
02 hex
0000 hex
Parameter
Register address
Word count
Byte count
Options
 Response Formats
• Normal Response
Byte-0
Byte-1
Transaction identi-
fier
X
X
Parameter
Register address
Word count
• Error Response
Byte-0
Byte-1
Transaction identi-
fier
X
X
Parameter
Exception code
 Execution Examples
Execution to Initialize Target Levels of All RF Tags Monitored by Reader/Writer in Focus Mode
TX: 000000000009FF10A3000001020000
RX: 000000000006FF10A3000001
7 - 56
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
0009 hex
Byte-14
The register address (A300 hex) that specifies resetting the focus
The number of words for the option (0001 hex)
The number of option bytes (02 hex)
0000 hex: No options
Byte-2
Byte-3
Byte-4
Byte-5
Protocol identifier
Field length
0000 hex
0006 hex
The register address from the command is set.
The word count from the command is set.
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
0003 hex
For details, refer to Exception Code on page 7-7 under 7-2-3 Response Format for
Error Completion on page 7-7.
Byte-5
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
10 hex
Description
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
10 hex
Description
Byte-5
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
90 hex
Description
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Byte-8
Byte-9
Byte-10
Byte-11
Register address
Word count
A300 hex
0001 hex
Byte-8
Byte-9
Byte-10 Byte-11
Register address
Word count
A300 hex
0001 hex
Byte-8
Excep-
tion code
1 byte