Omron V780 Series User Manual page 281

Uhf rfid system reader/writer
Hide thumbs Also See for V780 Series:
Table of Contents

Advertisement

GET MOST RECENT COMMAND ERROR INFORMATION
 Function
This command is used to check the most recent command error information from the Reader/Writer.
The most recent command error information is cleared when the Reader/Writer is restarted.
 Command Format
Byte-0
Byte-1
Transaction identi-
fier
X
X
Parameter
Register address
Word count
 Response Formats
• Normal Response
Byte-0
Byte-1
Transaction identifier
X
X
Byte-9
...
Byte-12
Time information
4 bytes
Byte-23
Byte-24
Reader/Writer Number
2 bytes
Parameter
Byte count
Most recent
command error
information
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
0006 hex
The register address (D900 hex) that specifies reading the most recent command
error information
The number of words in the most recent command error information to read (000C
hex)
Byte-2
Byte-3
Protocol identifier
0000 hex
Byte-13
...
Byte-16
Most recent command error information
IP address of the remote
device
4 bytes
Byte-25
Byte-26
Byte-27
Most recent command error information
Attached information 1
4 bytes
The number of bytes in the most recent command error informa-
tion that was read (18 hex)
Time information
Gives the time information in 8-digit hexadecimal
IP address of the remote
Gives the IP address that was read in 8-digit hexadecimal.
device
Example: C0A801C8 hex (192.168.1.200)
Transaction identifier
The transaction identifier specified in the command that produced
the error
Command code
Gives the command code in 8-digit hexadecimal.
Error code
For details, refer to 9-2-1 Command Errors on page 9-4.
Reader/Writer Number
This displays the Reader/Writer number of the reader/writer com-
municating with the RF Tag in 4 hexadecimal digits.
* This is 0000 hex if Multi-Reader/Writer mode is disabled or if
Attached information 1
Gives additional information 1 on the error in 8-digit hexadecimal.
Attached information 2
Gives additional information 2 on the error in 8-digit hexadecimal.
7 Modbus/TCP Communications
Byte-5
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
03 hex
Description
Byte-4
Byte-5
Byte-6
Field length
Unit identifier
001B hex
FF hex
Byte-17
Byte-18
Byte-19
Transaction identifier
Command code
2 bytes
Byte-28
Byte-29
Byte-30
Attached information 2
Description
there is a command error.
Byte-8
Byte-9
Byte-10
Byte-11
Register address
Word count
D900 hex
000C hex
Byte-7
Byte-8
Function code
Byte count
03 hex
18 hex
Byte-20
Byte-21
Byte-22
Error code
2 bytes
2 bytes
Byte-31
Byte-32
4 bytes
7 - 129
7

Advertisement

Table of Contents
loading