7 Modbus/TCP Communications
EXTENDED DATA WRITE
Function
This command writes data to the RF Tag in the communications range.
You can specify writing up to 2,048 words with one EXTENDED DATA WRITE command.
Command Format
Byte-0
Byte-1
Transaction identi-
fier
X
X
Byte-12
Byte-13
Write size
2 bytes
Parameter
Field length
Subfunction code
Write area start address
Write size
Data to write
Options
Response Formats
• Normal Response
Byte-0
Byte-1
Transaction identi-
fier
X
X
Byte-12
...
StoredPC
2 bytes
7 - 46
Byte-2
Byte-3
Byte-4
Protocol identifier
Field length
0000 hex
000C to 100A hex
Byte-14
...
Data to write
1 to 2,048 words (2 to 4,096 bytes)
Setting range: 000C to 100A hex
0002 hex: EXTENDED DATA WRITE
Specify in 4-digit hexadecimal the start address for writing data in the RF Tag.
Setting ranges (word address specifications)
0000 to 07FF hex: Reserved area
1000 to 17FF hex: UII (EPC) area
2000 to 27FF hex: TID area
3000 to 3FFF hex: User area
Specify in 4-digit hexadecimal the number of words of data to write.
Setting range: 0001 to 0800 hex (2,048 words max.)
The data to write
For details, refer to 7-3 RF Communications Command Options on page 7-10.
Byte-2
Byte-3
Byte-4
Byte-5
Protocol identifier
Field length
0000 hex
2 bytes
...
...
...
Options
0 to 70 bytes
UII (EPC code)
Reception level
62 bytes
2 bytes
Byte-5
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
64 hex
Byte-n
+ n
Options
2 bytes
Description
Byte-6
Byte-7
Unit
Function
identifier
code
FF hex
64 hex
...
...
...
Diagnostic results
2 bytes
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Byte-8
Byte-9
Byte-10
Byte-11
Subfunction code
Write area start
address
0002 hex
2 bytes
Byte-8
Byte-9
Byte-10 Byte-11
Subfunction code
Error code
0002 hex
0000 hex
...
Byte-n
Reader/Writer
Number
2 bytes