6-10 Multi-Reader/Writer Function; 6-10-1 Outline - Omron V780 Series User Manual

Uhf rfid system reader/writer
Hide thumbs Also See for V780 Series:
Table of Contents

Advertisement

6-10 Multi-Reader/Writer Function

6-10-1 Outline

The Multi-Reader/Writer function allows connection to multiple Reader/Writers, and performs com-
munications with RF Tags.
It can connect to a maximum of eight Reader/Writers, and performs master/slave control with one
Reader/writer as the master, and the other Reader/Writers as slaves. Because multiple slave
Reader/Writers can be jointly controlled simply by controlling a master Reader/Writer, it is possible
to easily perform complicated controls from the host device.
Slave Reader/Writer
Slave Reader/Writer
(Reader/Writer No.7)
(Reader/Writer No.2)
...
Control
In the Multi-Reader/Writer function, the slave Reader/Writers connected to the master Reader/Writer
are differentiated by the following Reader/Writer numbers.
Reader/Writer Type
Master Reader/Writer
Slave Reader/Writer 1
Slave Reader/Writer 2
Slave Reader/Writer 3
Slave Reader/Writer 4
Slave Reader/Writer 5
Slave Reader/Writer 6
Slave Reader/Writer 7
Precautions for Correct Use
• When using this function, the Reader/Writers connected by the Multi-Reader/Writer function
must all be Version 3.0 or later.
• When using this function, the Reader/Writers connected by the Multi-Reader/Writer function
must all be the same model (country of specification).
• The Slave Reader/Writer (V780-HMD68-ETN--S) does not accept communications com-
mands or Reader/Writer setting commands.
Also, it does not accept Modbus/TCP port connection from other than the Master Reader/ Writer.
*1. When using a standard Reader/Writer (V780-HMD68-ETN-) as a slave Reader/Writer, the Getting
command will be accepted.
*2. Connection from the web port will be accepted.
• The slave reader/writer (V780-HMD68-ETN--S) can not be used as a master reader/writer.
• The Modbus/TCP port number of the slave Reader/Writer must be set the default (502).
When changed, "Communications error between Reader/Writers (200B hex)" is detected.
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Slave Reader/Writer
(Reader/Writer No.1)
RF Tag
Control
Control
Reader/Writer Number
0
1
2
3
4
5
6
7
Host device
(PLC, etc.)
Command
Response
Switching Hub
Remarks
The Reader/Writer numbers are not used when the
Multi-Reader/Writer function is disabled.
The Reader/Writer numbers will be moved forward by the
number of slave Reader/Writers. (Configuration with middle
numbers missing is not possible)
* 1
6 Functions
Master Reader/Writer
(Reader/Writer No.0)