Omron V780 Series User Manual page 315

Uhf rfid system reader/writer
Hide thumbs Also See for V780 Series:
Table of Contents

Advertisement

Item name
Testing
Read ID
Result
Operating
Measurement graph
RF Tag list
UII (EPC
code)
No. of
comms
Target level
For information on focus monitoring, refer to 6-9-5 Focus Monitor on page 6-54.
 Saving Files
You can click the Save Button on the Focus Monitor Tab Page to save the focus information at a speci-
fied path and file name. The focus information is saved in a CSV file in the following format.
CSV Format
No, Time, UII (EPC), Target level
1 <time>, <UII (EPC code)>, <target_level>
2 <time>, <UII (EPC code)>, <target_level>
3 <time>, <UII (EPC code)>, N/A (Test ID READ)
4
:
:
Item name
No
Time
UII (EPC)
Target level
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Description
Select this option to test operation for communications in
Focus Mode.
Click this button to execute test communications with ID
READ during monitoring.
When you click this button, the RF Tag with the highest target
level on the right edge of the measurement graph will be
selected as the RF Tag in front of the Reader/Writer.
The UII (EPC code) of the RF Tag that was communicated
with is displayed as the result of test communications with ID
READ. If communications failed, the background will change
to red.
Select this operation to check the target levels of the
Reader/Writer during operation in Focus Mode.
This broken-line graph displays the target level against time
for each RF Tag during monitoring.
This list displays the UIIs (EPC codes) of the RF Tags that
were detected during monitoring.
Displays the numbers of communications with the RF Tags
during monitoring.
Displays the current target levels measured during monitor-
ing numerically and as a bar graphs.
This is displayed when testing communications
:
with ID READ.
Description
Gives index numbers in chronological order.
1 to 360 (500-ms sampling × 360 samples)
Gives the time when the RF Tag target level was measured
during monitoring.
hh:mm:ss.sss
hh: hour, mm: minutes, ss.sss: seconds (millisecond
increments)
Gives the UIIs (EPC codes) of the RF Tags that were
detected during monitoring in hexadecimal.
XX ... XX hex
Gives the target level measured during monitoring.
00 to 100: Target level
When test communications with ID READ are performed, the
following text is output.
"N/A(Test ID READ)"
8 Browser Interface
Remarks
The data is plotted
for 60 s.
Remarks
Data is output for
up to 3 minutes.
The time is syn-
chronized with the
computer on which
the Web browser is
running.
The target level for
RF Tag what have
already executed
the RF communi-
cations command
will be 0.