Omron V780 Series User Manual page 347

Uhf rfid system reader/writer
Hide thumbs Also See for V780 Series:
Table of Contents

Advertisement

Error name
RF Tag verification error
Verification was performed for the results of writing data to the RF Tag, but inconsistencies were
Description
discovered.
Detection timing
At RF communications execution
Log category
Command error log
Additional infor-
None
mation 1
(1) There is no RF Tag in the stable communications range of the RF Tag.
Probable cause
(2) The ambient environment is affecting operation (radio wave interference or surrounding metal).
(3) Collision occurred for responses from more than one RF Tag.
Execute the command again. If the same error still occurs, try the following measures.
Workaround
Make sure there is an RF Tag in the stable communications range.
Adjust the execution timing of the command to start communications with the RF Tag.
Precautions/
Remarks
Error name
RF Tag system error
Description
The RF Tag returned an error response.
Detection timing
At RF communications execution
Log category
Command error log
Additional infor-
Manufacturer analysis code
mation 1
Probable cause
(1) The RF Tag does not support the RF communications protocol of the Reader/Writer
(ISO-18000-6C (Gen2)).
Log category
(2) The RF Tag is faulty.
Consult with your OMRON representative concerning RF Tags that can communicate with the
Reader/Writer.
Workaround
Replace the RF Tags with RF Tags that can communicate with the Reader/Writer.
Precautions/
Remarks
Error name
Password error
Description
The access password does not match the RF Tag.*
Detection timing
At RF communications execution
Log category
Command error log
Additional infor-
None
mation 1
Probable cause
The access code in the RF Tag and the access code set in the Reader/Writer do not agree.
Workaround
Check the access password set in the RF Tag.
Precautions/
Remarks
*1. When the environment is unstable, this error can occur even if the access password is correct.
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Error code
2006 hex
Recovery method
None
Additional infor-
None
mation 2
Error code
2008 hex
Recovery method
None
Additional infor-
Manufacturer analysis code
mation 2
Error code
2009 hex
Recovery method
None
Additional infor-
None
mation 2
9 Troubleshooting
9 - 13
9

Advertisement

Table of Contents
loading

Table of Contents