Omron V780 Series User Manual page 339

Uhf rfid system reader/writer
Hide thumbs Also See for V780 Series:
Table of Contents

Advertisement

RF Tag Communications Errors
Error name
RF Tag missing error
RF Tag communications
failed
(Reserved)
RF Tag address error
RF Tag lock error
RF Tag verification error
(Reserved)
RF Tag system error
Password error
(Reserved)
Communications error
between Reader/Writers
(Reserved)
Communications canceled
Communications aborted
*1. When the environment is unstable, this error can occur even if the access password is correct.
UHF RFID System V780-series Reader/Writer User's Manual (Z389)
Error code
2001 hex
There is no RF Tag in the communications range.
Communications with the RF Tag did not end normally.
2002 hex
---
The access address for the RF Tag is outside of the area sup-
2004 hex
ported by the target RF Tag.
2005 hex
Access to an area that is locked in the RF Tag failed.
Verification was performed for the results of writing data to the RF
2006 hex
Tag, but inconsistencies were discovered.
---
2008 hex
The RF Tag returned an error response.
2009 hex
The access password does not match the RF Tag.*
---
The master Reader/Writer will establish communications with the
200B hex
slave Reader/Writers during execution of the Multi-Reader/Writer
function.
---
Processing was canceled when a STOP command was received
2011 hex
before an RF Tag was detected. (The contents of the RF Tag was
not changed, even for a DATA WRITE command.)
Processing was aborted when a STOP command was received
2012 hex
during communications with an RF Tag.
9 Troubleshooting
Description
9
9 - 5

Advertisement