Example 2: Encoder with Status Data
MSB
b27 b26
b25
b24 b23
Data Length (bits): 28
Multi-Turn Data Length (bits): 12
Multi-Turn Data Start Bit: b27
Single-Turn Data Length (bits): 13
Single-Turn Data Start Bit: b15
Status Data Length (bits): 3
Status Data Start Bit: b2
Parity Check: No check
Example 3: Encoder with Parity Check
Data Length (bits): 18
Multi-Turn Data Length (bits): 0
Single-Turn Data Length (bits):17
Single-Turn Data Start Bit: b17
Status Data Length (bits): 0
Parity Check: Even parity check
Parity Check Bit: b0
Parity Check Start Bit: b17
Parity Check Length (bits): 17
4.
Monoflop Time
The Monoflop Time parameter determines the interval time between two SSI data frames. The correct position data
can be received as long as the setting value is greater than that specified for the connected encoder. The range is
set as follows.
CLK
DATA
Parameter
Monoflop time
Ch ap te r 14 H igh Spe ed Cou n te r Mod ul e AS02HC
b22 b21 b20 b19
b18 b17
b16 b15 b14 b13
Multi-turn data
MSB
b17
b16 b15 b14 b13
b12
b11 b10
MSB
Setting
4 ~ 2500
b12
b11 b10
b9
b8
b7
Single-turn data
b9
b8
b7
b6
b5
b4
b3
b2
Single-turn data
Monoflop
Time
LSB
Unit
16us
LSB
b6
b5
b4
b3
b2
b1
b0
Status
data
LSB
b1
b0
Parity
MSB
Default
4
1 4 - 1 5
14

Hide quick links: