AS Ser ies M od ul e Man ua l
CR#
7
8
9
10
11
12
13
14
15
16
17
18
19–58
_8
59
60
8 - 6
Name
Filter mode for CH1
Maximum filter for CH1
Average weight measured
times for CH1
Upper limit of the zero return
for CH1
Lower limit of the zero return
for CH1
Zero point tracking time for
CH1
Zero point tracking range for
CH1
Calibration points for CH1
Calibrated weight for CH1
Display options for CH2
Eigenvalue for CH2
Description
weight measured exceeds the limit, an
alarm is triggered. The value should be
greater than 1.
0: no filter (default)
1: maximum filter mode
2: average filter mode
Range: 0–8; the bigger the number the
stronger the filter
Range: 1–100
(for FW V1.04: 1–400 is available)
Floating-point format
Determines the current weight as the zero
point in the upper/lower range; when the
lower range is larger than the upper range,
the lower range is read as the upper range
and vice versa.
Range: 5–500
Unit: 100 ms
Floating-point format
Range: 0–10000; 0: disabled
Range: 2–20
Floating-point format
Calibrated weight of the calibration points
1–20
0: disabled
1: gross weight
2: net weight
3: raw data
0:1 mV/V
1:2 mV/V
2:4 mV/V
Att.
Default
R/W
0
R/W
1
R/W
10
R/W
10
R/W
-10
R/W
10
R/W
0
R/W
2
R/W
-
R/W
1
R/W
1