13.4.4 Application of Delta Special Driver & AS Remote Mode
The device list in the following example is the same as that in section12.4.3.
Complete the following setups before the AS00SCM-A module is powered on.
1.
The AS-FCOPM card is inserted to AS00SCM-A via Card 2. (The 120Ω terminal resistor is enabled.)
2.
Use Delta standard cable to connect to AS CPU and the mode switch is turned to RTU mode.
_13
3.
Four switches are set to ID1: 0 / FORMAT1: 8 / ID2: 9 / FORMAT2: 7and the status is set to Delta Special Driver &
AS Remote Communication, node ID 9 and baud rate 1Mbps.
4.
AS04SIL-A is connected on the right side of AS00SCM (RTU). Ensure that IO-Link devices are connected to the four
ports according to the wiring in section 13.2.3.
Switch the power on after the AS-FCOPM card is inserted to AS332T-A via Card 2. (The 120Ω terminal resistor is
enabled.) Open the HWCONFIG 4.0 software, set up function card 2 for AS CPU and then download the settings as
follows.
The following steps are the same as the operation in section 13.4.3.
1 3 - 3 2
Model name
AS332T-A
AS00SCM-A
AS04SIL-A
AI-B100
E3S-DCP21-IL3
MAXREFDES27#
MAXREFDES36#
Device type
PLC
RTU
IO-Link Master
3
rd
IO-Link Device
3
rd
IO-Link Device
3
rd
IO-Link Device
3
rd
IO-Link Device