AS Ser ies M od ul e Man ua l
13.2.2 Profile
7
8
_13
Number
1
Model name
POWER LED indicator (Blue)
Module LED indicator
(Red)
Network LED indicator
(Orange)
2
C1, C2, C3, C4 LED indicator
(Orange)
Q1, Q2, Q3, Q4 LED indicator
(Orange)
E1, E2, E3, E4 LED indicator
(red)
3
Removable terminal block
1 3 - 6
CQ 1
CQ2
CQ3
CQ4
Name
Model name of the module
Indicates the status of the power supply
ON: the power is on
OFF: no power or the power voltage is too low
Error status of the module
OFF: The module is normal.
ON: The communication with its left-side PLC or RTU module fails.
Blinking:
1.
Module setting or communication error (blinks every 1 second)
2.
Hardware or low voltage error (blinks every 0.2 second)
Error status of the network
ON: No external power supply
Blinking: Scanning is ongoing or the module is already configured and
the diagnosis is done.
OFF: The module has been configured but the diagnosis has not done
yet.
IO-Link connection status of each communication port
ON: The communication port is in IO-Link mode and a device is
connected.
Blinking: The communication port is in IO-Link mode but no device is
connected or the device connected is not configured.
OFF: The communication port is disabled or in SIO mode.
Indicates the status of input / output in SIO mode
ON: The input/output is working in SIO mode.
OFF: The communication port is disabled or in IO-Link mode.
Indicates if any warning or error occurs in each communication port of
the IO-Link connection.
Blinking: A warning or an error occurs
OFF: No warnings or errors
IO-Link
38.2
1
04 SI L
L1+
PWR
-
DI 1
L1
2
MS
L2+
NS
DI2
-
L2
C1
Q1
L3+
E1
C2
-
3
DI3
L3
Q2
E2
L4+
C3
-
DI4
L4
Q3
4
E3
24 V
C4
0V
Q4
E4
5
6
35
Unit: mm
Description
95
7
75