C R # 2 0 0 : Codes for the state register
Explanation
Bit
Code
b0
16#0001 Error exists in the power supply.
b2
16#0004 Error exists in the driver board.
b4
16#0010 Reserved
b6
16#0040
b8
16#0100
b10 16#0400 CH1 has been adjusted incorrectly.
b12 16#1000 CH1 is not measuring any weight.
b14 16#4000
Note: The state is determined by the corresponding bit and it is possible to have more than 2 states at the
same time.
C R # 2 0 1 : Command set
Explanation
Input
value
_8
0
1–20
21–40
98
99
8 - 1 0
Definition
The weight measured by CH1
exceeds the maximum weight that
can be measured, or the voltage of
SEN is incorrect.
The weight measured by CH1
exceeds the maximum weight that
can be measured.
The weight measured by CH1 is in
the stability range specified.
Description
No action
Commands for calibrating the calibration
points 1–20 on CH1
Commands for calibrating the calibration
points 1–20 on CH2
Activate the weight calibration.
Deactivate the weight calibration.
Bit
Code
b1
16#0002 Error exists in the module hardware.
b3
16#0008 Calibration disabled
b5
16#0020 Reserved
The weight measured by CH2
exceeds the maximum weight that
b7
16#0080
can be measured, or the voltage of
SEN is incorrect.
The weight measured by CH2
b9
16#0200
exceeds the maximum weight that
can be measured.
b11 16#0800 CH2 has been adjusted incorrectly.
b13 16#2000 CH2 is not measuring any weight.
The weight measured by CH2 is in
b15 16#8000
the stability range specified.
Input value
Description
Start a new recording of the peak value
16#0101
for CH1.
Start a new recording of the peak value
16#0102
for CH2.
Start a new recording of the peak value
16#010F
for CH1 - CH2.
16#0201
Start a new recording for CH1.
16#0202
Start a new recording for CH2.
Definition