Delta AS Series Manual page 20

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

1.2.2.3 Conducted Immunity Test
Environmental Phenomenon
Reference Standard
Interface/Port
Shielded cable
Data communication
Unshielded cable
AC I/O (unshielded)
Digital and analog I/O
Analog or DC I/O
(unshielded)
All shielded lines (earth)
AC power
Equipment power
DC power
AC I/O and AC auxiliary
power
I/O power and
auxiliary power output
DC I/O and DC auxiliary
power
Fast Transient
Specific Interface/Port
Ch ap te r 1 In tro duc tio n
High Energy
Burst
Surge
IEC 61000-4-4
IEC 61000-4-5
Test Level
Test Level
1 kV
1 kV CM
1 kV
1 kV CM
2 kV CM
2 kV
1 kV DM
1 kV
1 kV CM
1 kV
1 kV CM
2 kV CM
2 kV
1 kV DM
0.5 kV CM
2 kV
0.5 kV DM
2 kV CM
2 kV
1 kV DM
0.5 kV CM
2 kV
0.5 kV DM
1_
Radio
Frequency
Interference
IEC 61000-4-6
Test Level
10 V
10 V
10 V
10 V
10 V
10 V
10 V
10 V
10 V
1 - 7