(23) Put the cables that are disconnected in step (3), into the wiring binders.
n
Confirm that the two cables are not twisted and are laid parallel.
(24) Connect the Robot cable to the connector (CN100) on the CB-117 board.
(25) Fix the cable using the new binding band supplied, at the position where the binding band was
removed in step (2).
n
When laying the Robot cable, gather up the excessive length of the cable at part A as shown in
the figure.
(26) Attach the X cable cover with two screws (PWH4 x 8).
(27) Check that the connection of the Runner flex around the X cable is not disconnected or loose at
any position. Check whether the transfer unit moves freely from an end stopper of the connected
rail to the other end stopper of it. Especially, confirm that the cable unit that runs from X
CABLE BRACKET (CBL-YR) to CB-117 does not touch the walls when the transfer unit is
moved to the basic console.
4-46
CB-117 board
CN100
Portion A
PWH4 x 8
X cable cover
Guide channel (EX3)