Sony CSM-100BS Operating Instructions Manual

Sony CSM-100BS Operating Instructions Manual

Consolidated storage management system
Hide thumbs Also See for CSM-100BS:

Advertisement

Quick Links

CONSOLIDATED STORAGE MANAGEMENT SYSTEM
CSM-200BF/200BS
CSM-100BF/100BS
CSM-60BF/60BS
CSM-200D
CSM-200C
CSM
OPERATION MANUAL
[Japanese/English]
1st Edition (Revised 1)

Advertisement

Table of Contents
loading

Summary of Contents for Sony CSM-100BS

  • Page 1 CONSOLIDATED STORAGE MANAGEMENT SYSTEM CSM-200BF/200BS CSM-100BF/100BS CSM-60BF/60BS CSM-200D CSM-200C • • OPERATION MANUAL [Japanese/English] 1st Edition (Revised 1)
  • Page 2 • • •...
  • Page 3 2(J) ........................4(J) ........................5(J) ......................... 9(J) ................10(J) ....................14(J) ........................19(J) ........................27(J) ........................1 (J)
  • Page 4 • • • • 2 (J)
  • Page 5 3 (J)
  • Page 6 4 (J)
  • Page 7 PetaSite S200 CSM-200BF/200BS/100BF/100BS/60BF/60BS Ethernet CSM-200D/200C Storage Area Network PetaSite S200 (PetaSite 5(J)
  • Page 8 PetaSite S200 (TB) S-AIT (PetaSite Control Unit) CSM-200BF/200BS CSM-200C (TB) 6(J)
  • Page 9 CSM-200D/CSM-200C CSM-200BF/200BS 7(J)
  • Page 10 CSMU-100B Upgrade Kit CSM-60BF/BS to CSM-100BF/BS CSMA-DR130F Storage Management System Drive Unit (FC) CSMU-200B Upgrade Kit CSM-100BF/BS to CSM-200BF/BS CSMA-DR100S Storage Management System Drive Unit (SCSI) DMSA-CPJ Power Cord CSMA-CBLL Extension Kit (CL) DMSA-CPE Power Cord CSMA-CBLS Extension Kit (CS) CSMA-BLTL Extension Kit BL CSMA-BLTS Extension Kit BS CSMA-PSL Redundant Power Unit (Library)
  • Page 11 • • PetaSite • • • • • • • • • 9(J)
  • Page 12 CSM-200BF/200BS/100BF/100BS/60BF/60BS POWER READY BUSY ERROR ESC/ INITIAL MENU ENTER OPEN IN/OUT 9 10 11 12 OPEN PetaSite 10(J)
  • Page 13 PetaSite • • • • IN/OUT 11(J)
  • Page 14 MENU INITIAL READY BUSY ERROR POWER READY BUSY ERROR ESC/ INITIAL MENU ENTER ENTER MENU ESC/CLR ENTER ESC/CLR INITIAL READY BUSY ERROR Initial Request Full Initial Request Power off Request 12(J)
  • Page 15 IN/OUT PetaSite NO MAGAZINE OPEN IN /OUT OPEN MAGAZINE OPEN MAGAZINE POWER NO MAGAZINE POWER IN/OUT OPEN 13(J)
  • Page 16 PCU Ethernet I/F Ethernet I/F NetApp HP-UX SUN Solaris 500GB 500GB PetaSite Ethernet I/F PetaSite PetaSite PetaSite S200 PetaSite PetaServe/PetaBack 14(J)
  • Page 17 DZC-PSC2 DZC-PSC2 root 15(J)
  • Page 18 # /osm/bin/app_sethostname [Ctrl] [Alt] [F6] # /usr/bin/redhat-config-xfree86 --noui --reconfig # /sbin/init 6 # /usr/sbin/timeconfig • • DZC-PSC2 2002 1 23 4 56 # /bin/date 0123045602 16(J)
  • Page 19 NPX_PLUGIN_PATH="{JRE }/plugin/ sparc/ns4" • export NPX_PLUGIN_PATH • setenv BROWSER {Netscape }/netscape setenv XAPPLRESDIR {Netscape default setenv XAPPLRESDIR /usr/openwin/lib/locale/ ja/app-defaults Windows #setenv BROWSER /usr/bin/netscape UNIX Solaris 2.6/7/8 Red Hat Linux 7.1/8.0 Windows PetaApp Monitor GUI Solaris Monitoring & Maintenance Terminal GUI PetaBack GUI setenv JAVABIN {JRE }/bin/java...
  • Page 20 UNIX PetaApp Monitor GUI % {DZC-PSC2 }/bin/petaapp Monitoring & Maintenance Terminal GUI PetaBack GUI 18(J)
  • Page 21 # /sbin/init 0 # /sbin/poweroff Halting system..Stopping all md devices. Power down 19(J)
  • Page 22 20(J)
  • Page 23 Set Up Hours Meter Program Version Set Up Configuration 21(J)
  • Page 24 (Repair filesystem) 2# init 6 # /sbin/init 6 /export/home:UNEXPECTED INCONSISTENCY; RUN fsck MANUALLY. (i.e., without -a or -p options) *** An error occurred during the file system check. *** Dropping you to a shell; the system will reboot *** when you leave the shell. Give root password for maintenance (or type Control-D for normal startup) *** An error occurred during the file system check.
  • Page 25 DZC-PSC2 (Repair filesystem)2# init 6 UPS Uninterrupted Power Supply PetaServe/ PetaBack 23(J)
  • Page 26 PetaApp Linux Hostname/IP Address (eth0) (eth1) GPL/LGPL CSM-200BF/200BS/100BF/100BS/60BF/ 60BS • • IP Address http://www.sony.net/Products/Linux/ IP Address Port Number SILKWORM 3800/3200 IP Address 24(J)
  • Page 27 DZC-PSC2/MMT DZC-PSC2/MMT – 25(J)
  • Page 28 CSMA-DR100S/CSMA-DR130F CSMA-DR100S CSMA-DR130F 26(J)
  • Page 29 CSM-200BS/100BS/60BS CSM-200BF/100BF/60BF CSM-200D CSM-200C 27(J)
  • Page 30 S-AIT 11.1 mm 28(J)
  • Page 31 WARNING: THIS WARNING IS APPLICABLE FOR USA WARNING ONLY. To prevent fire or shock hazard, do not expose the unit to rain or moisture. If used in USA, use the UL LISTED power cord specified below. To avoid electrical shock, do not open the cabinet. Refer DO NOT USE ANY OTHER POWER CORD.
  • Page 32 LED Notice: The LED of the barcode reader incorporated inside this product complies with IEC 60825-1. This product is classified as a CLASS 1 LED PRODUCT. LED (barcode reader) Wavelength 630–660 nm For models with FC-conforming SAIT drives Laser Notice: The equipment contains tape drives using laser that complies with IEC 60825-1.
  • Page 33: Table Of Contents

    Table of Contents Overview ....................4(E) Product Line-up of the PetaSite S200-Series ........4(E) Features of the PetaSite S200-Series ..........5(E) Extension Example ................6(E) System Equipment ................7(E) Notes on Maintaining the Performance of the System ..................8(E) Locations and Functions of Parts ............9(E) Front and Side .................9(E) Display Panel .................11(E) IN/OUT Ports ................12(E)
  • Page 34: Overview

    SCSI speed. It contains the PetaSite Control Unit and DZC- CSM-100BF PSC2 PetaSite control software in the Basic Storage Max. 108 Max. 54TB System models as a package. CSM-100BS SCSI CSM-60BF Max. 60 Max. 30TB CSM-60BS SCSI Using the optional CSMA-PSL power unit dedicated...
  • Page 35: Features Of The Petasite S200-Series

    Cassette management using bar codes Features of the PetaSite S200- The system includes a barcode reader to aid in Series management of cartridges with barcode labels attached to the cartridges. The CSM System works in a heterogeneous environment. Its SAN solution makes this high-speed Easy control backup subsystem possible.
  • Page 36: Extension Example

    Overview Extension Example Data capacity can be increased by connecting up to seven CSM-200D/200C Extension Consoles to the CSM-200BF/200BS Basic Storage System. CSM-200BF/200BS CSM-200D/200C Note The Extension Consoles cannot be connected to the CSM-100BF/100BS/60BF/60BS. To connect one, upgrade the CSM-100BF/100BS/60BF/60BS to the CSM-200BF/200BS using the appropriate Upgrade Kit (option).
  • Page 37: System Equipment

    CSMU-200B Upgrade Kit CSM-100BF/100BS to System Equipment CSM-200BF/200BS This is the kit to upgrage the CSM-100BF/100BS to CSMA-DR130F Storage Management System the CSM-200BF/200BS. Drive Unit (FC) This is the hot-swapping FC drive unit (attachment DMSA-CPE Power Cord included) for dedicated use with libraries. This is the power cord for the PetaSite S200-series and the PetaSite Control Unit (PCU) (AC 120 V).
  • Page 38: Notes On Maintaining The Performance Of The System

    Notes on Maintaining the Performance of the System Pay attention to the following points when handling Mounting the PetaSite Control Unit the system equipment and media, so as not to damage A specially trained technician must mount the PetaSite them and to maintain top performance. Control Unit.
  • Page 39: Locations And Functions Of Parts

    Locations and Functions of Parts Front and Side CSM-200BF/200BS/100BF/100BS/60BF/60BS Inside front Front panel POWER READY BUSY ERROR Display panel check window ESC/ 3 Display panel INITIAL MENU ENTER OPEN 4 IN/OUT port 9 10 11 12 OPEN Slot for optional redundant power unit (for DRIVE) 1 DRIVE power switch Slot for optional drives...
  • Page 40 Locations and Functions of Parts 1 DRIVE power switch 5 PetaSite Control Unit This is for turning the power to the drive block on and The unit controls and monitors the drives and robot off. block. When turning on the power, set it to the I position For details, see “PetaSite Control Unit (PCU)”...
  • Page 41: Display Panel

    Turn the power off and then on again. 2 READY indicator 3 BUSY indicator If the problem persists after executing the above, 4 ERROR indicator consult Sony service personnel. 5 Display window The operating condition, menu items, or values are POWER READY BUSY ERROR displayed here.
  • Page 42: In/Out Ports

    Locations and Functions of Parts IN/OUT Ports PetaSite Control Unit (PCU) The unit controls and monitors the drives and robot block. It also functions as the application server for PetaServe 1 NO MAGAZINE indicators 4 OPEN buttons and PetaBack. 3 Function buttons 2 IN/OUT indicators OPEN MAGAZINE...
  • Page 43: Preparations

    Preparations Installation Ethernet Interface Ports of the A technician specially trained for CSM system and PetaSite-series equipment must perform setting and The PCU has two Ethernet interface ports: one for the wiring the units, and making system environment local network to control the PetaSite system, and settings.
  • Page 44: Settings

    The host name and IP address can not be changed after button of the MMT window of the DZC-PSC2. starting operation of the CSM System. If you need to change them, contact to Sony support center. Starting the DZC-PSC2 Type “root” in the Username box to log in, and Follow the procedures below to start the DZC-PSC2.
  • Page 45 Enter the command shown below and press the If no display appears after changing the Enter key to execute the command. PCU settings # /osm/bin/app_sethostname Press [Ctrl]+[Alt]+[F6] simultanously. Type “/sbin/init 6” in the Terminal window opened in step 1 and press the Enter key to restart Log in as a root user.
  • Page 46 Preparations • To use the on-line help for the remote maintenance Set the environmental variables BROWSER and tool, you need a Web browser. Operation with the XAPPLRESDIR with the startup file of the on-line Web browsers shown below has been confirmed. help {folder where DZC-PSC2 has been installed}/ bin/webhelp as shown below.
  • Page 47 For UNIX: To start the PetaApp Monitor GUI: Enter the command below. %{folder where the DZC-PSC2 has been installed}/bin/ petaapp where % is the command prompt. The PetaApp Monitor GUI is activated. To start the Monitoring & Maintenance Terminal GUI: Click on the PetaSite button of the PetaApp Monitor GUI, and the Monitoring &...
  • Page 48: Operations

    Operations Starting Up Ending Set both the DRIVE and ROBOT power switches Terminate all applications of the CSM-200BF/200BS/100BF/100BS/60BF/ 60BS to the I position (ON). Check that no cartridge is installed in any drive. If an optional fibre channel switch has been Terminate the PCU following the procedures installed in the system, turn it on.
  • Page 49: Installing Or Removing Cartridges

    To load a cartridge, put a cartridge in the magazine so that its bar code can be read and the side with Install or remove cartridges using the following character indication, such as “SONY,” faces the procedure: direction shown in the figure below.
  • Page 50: Menu Operation

    Operations Setting the items in Set Up menu Menu Operation Items on the Set Up menu can be set using the When you press the MENU button on the display following procedures. panel, one of the following menu items appears in the display window.
  • Page 51: Restarting The Pcu

    When “(Repair filesystem)2#” appears, type Restarting the PCU “init 6,” then press the Enter key to restart the unit. Type “root” in the Username box to log in. The display changes to “(Repair filesystem)2# init 6.” Type the following in the Terminal window. If the repair is completed, the unit starts up normally.
  • Page 52: Operations Of The Dzc-Psc2

    /osm/doc directory. For information on the configuration to use the preinstalled PetaServe/PetaBack and the interconnection environments, ask your Sony dealer. To apply PetaServe and PetaBack in practical operation, you may continue to use them by purchasing the formal software license.
  • Page 53: Petaapp Linux

    PetaApp Linux Initial Settings of Device The PCU adopts PetaApp Linux as the OS. Sony Settings at the factory are as shown below. Corporation has specially designed PetaApp Linux for the PetaSite Control Unit based on the RedHat Linux 8.0 ftp version. In the window, messages related to RedHat Corporation may appear, but RedHat Hostname/IP Address (eth0) : petalocal.petadomain...
  • Page 54 Operations DZC-PSC2/MMT If Mail/Remote Maintenance of Setup has not been set, initial settings are not required. Items DXC-PSC2/MMT Communication Port Condition TerminalServer 10.0.0.30, 10001 TerminalServer 10.0.0.40, 10001 Bin Division no setting (to be set depending on the user system configuration) Reserve Bin no setting Drive Condition...
  • Page 55 CSMA-DR100S/CSMA-DR130F Items CSMA-DR100S CSMA-DR130F Vendor ID (0 – 99999999) Vendor name (8 characters) SONY SONY Vendor ROM version (4 characters) 1.?? 1.?? Machine name (16 characters) SDZ-100 SDZ-130 Interface (0: SCSI-WD/1: SCSI-WS/2: SCSI-UWD/3: SCSI-LVD/ 8: Fibre channel/12: VRP) Series (0: SAIT-1 / 1: SAIT-2 / 2: SAIT-3 / 3: SAIT-4)
  • Page 56: Specifications

    Specifications General Accessories supplied Power requirements AC 100 V–240 V, 50/60 Hz CSM-200BS/100BS/60BS Power consumption Operation Manual (1) CSM-200BF/200BS/100BF/100BS/60BF/60BS Plug holder (8) 6.5 A–2.7 A Terminator (2) CSM-200C/200D Barcode label sheet (14) 3.5 A–1.5 A Barcode label sheet (for cleaning) (2) Dimensions (w/h/d) 680 1980 950 PetaApp Linux recover CD-ROM disk 1, disk 2...
  • Page 57: Specifications Of Sait

    Power unit CSMA-PSL (for redundant Specifications of Barcode Reader library) CSMA-PSD (for redundant The built-in bar code reader conforms to CODE 39, drive) and the specifications of the barcode labels are as Redundant drive interface board shown below. CSMA-DIF Upgrade kit CSMU-100B CSMU-200B Keyboard...
  • Page 58 The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual. Sony Corporation expressly prohibits the duplication of any...
  • Page 59: Sony Corporation

    Sony Corporation BC Company Printed in Japan CSM-200BF/200BS/100BF/100BS/ 60BF/60BS/200C/200D(SY) 2004.02.13 4-677-293-02(1) 2003...