Sony PetaSite CSM-200B Installation Manual page 129

Consolidated storage management system
Hide thumbs Also See for PetaSite CSM-200B:
Table of Contents

Advertisement

Initial Setup of PSC2 V4, V5 and V6
(Not required for PSC2 V3)
1. From the Setup Menu of MMT, select "PSC". Open the Setup PSC screen, and select the
"Communication" tag.
2. Select the line of "MIB-R". Press the "Revise" button to open the Communication screen.
3. In "Select Port", select "Terminal Server".
4. Enter IP Address as "10.0.0.41", and Port No. as "10001", and press the "OK" button.
(For PSC2 V5 and V6, follow steps 5 to 7 below. For PSC2 V4, follow steps 8 to 12 below).
For PSC2 V5 and V6
5. From the View Menu of MMT, select "Drive I/F status", and open the Drive I/F status screen.
6. In "Condition" of Redundant Drive I/F Trunk and Redundant Drive I/F Branch, select "Dual". Then
in the "Change Mode", select "Auto".
7. Press the "Apply" button. When "IN USE" and "STANDBY" appear in "Status", press the "OK"
button.
For PSC2 V4
8. From the View Menu of MMT, select "Drive Console Status", and open the Drive I/F status screen.
9. In "Redundant Drive I/F Board", select "Dual" and "Redundant".
10. Press the "Apply" button. Verify that "IN USE" appears in "Status" under "Redundant".
11. In "Redundant Drive I/F Board", select "Dual" and "Standard".
12. Press the "Apply" button. When "IN USE" appears in "Status" under "Standard", press the "OK"
button.
n
"UnKnown" appears in "Status" for unselected options.