(3) Connecting the CSM-200 system that contains the dual input power systems to the
UPS
n
If redundant power supplies for ROBOT and for DRIVE (product name: CSMA-PSL and CSMA-PSD)
are not installed, only two cords are sufficient for use.
When the shutdown function that enables status monitoring of the UPS is going to be used, connect the
UPS by either one of the following methods.
When enough capacity of the UPS can be secured, the connection using the method 1 is recommended, by
which an integrated shutdown processing can be performed.
1. Connect all the cables of PSC, DRIVE, and ROBOT to a single UPS.
UPS
and
Connect the serial interface status monitoring cable of UPS to the PSC serial interface.
For details, refer to Help on the PSC Monitoring & Maintenance Terminal of UPS.
6-6
AC inlet
for DRIVE (redundant)
AC inlet
for ROBOT (redundant)
AC inlet
for ROBOT (standard)
AC inlet
for DRIVE (standard)
UPS - AC inlet for ROBOT (standard)
UPS - AC inlet for DRIVE (standard)
UPS - PCU (redundant)
UPS - PCU (standard)
UPS - PCU
....
Power cord
....
Status monitoring cable
CSM-200