6. PSC2 Setup
6-1.
Preparation
(1) Turn on the power of the library (ROBOT, DRIVE).
(2) Start PetaApp Linux. When it has started before the library is turned on, restart it.
(3) Log into the "root" account, and start the terminal window.
(4) When the screen "PetaApp" is not open, double-click the "PetaApp" icon to open the "PetaApp".
Click the "Utility" to open the "PetaApp Utility" screen, and select the "Mode: Administrator" on the
upper-right of the screen. (the default password is "sony").
(5) Click the "PetaApp Utility" icon, and select the "SNMP" tag.
(6) Set the IP address of Terminal Server and FC-Switch, and check "polling".
Example of device settings
Terminal Server
No.
Polling
IP Address
1
Yes
10.0.0.30
2
Yes
10.0.0.40
3
Yes
10.0.0.41 ... When CSMA-DIF is used.
Fiber Channel Switcher
No.
Polling
IP Address
1
Yes
10.0.0.20 ... When the IP address of the FC switch is set 10.0.0.20 and the
(7) Enter "/psc/bin/pscend" and "/psc/bin/pscstart" on the terminal window.
(8) Select the "Network" tab, and set the end-user hostname and IP address to eth 1. Do not change eth 0.
(9) Restart.
n
When installing version PSC2 V5.01 or earlier onto DL360 G4, it is necessary to add items to the
registry.
Using PSC2 V5.01 in PetaApp V2.01 (for DL360 G4)
The V5.01 module can be used as is, but a new registry must be registered.
After installing PSC2 V5.01, execute "/psc/uty/regedt" and enter the following registry before
starting PSC.
Location: SNMP/PCU/ProLiant_DL360_G4
Key
Value Type
DriveArray
1
ExternalHealth 2
InternalHealth 1
4-104
network cable is connected to the built-in hub.
It is corresponds to the Brocade and QLogic, not to the old
McDATA.