18. Phase Adjustment
(1) Move the transfer to the extension console side. Move the phase adjustment pin of the Basic
storage system to the adjustment position.
(2) Push the X slider (top) and the X slider (bottom) against the phase adjustment pin. Then, check
the clearances at the top and bottom satisfy the specification.
Specification: Clearance must be 0.1 mm or less.
If the clearance does not satisfy the specification, loosen the hexagonal head cap bolt (M5 x 12)
and perform the phase adjustment until the specification is satisfied.
X slider (bottom)
4-38
Specification: The thickness gauge of 0.1 mm cannot be entered.
X slider (top)
Specification: The thickness gauge of 0.1 mm cannot be entered.
Phase
adjustment pin
Top surface
Phase adjustment pin
Phase adjustment pin
Floor surface
CSM-200