Sony PetaSite CSM-200B Installation Manual page 118

Consolidated storage management system
Hide thumbs Also See for PetaSite CSM-200B:
Table of Contents

Advertisement

5.
For only PSC V6.10 or earlier, perform the steps (5) to (7) by PetaBack/PetaServe in PC server.
(For PSC V6.20 or later, the host ID is set when installing the PSC.)
Set the host ID using the "PetaApp Maintenance Tool" prepared in (1).
Mount floppy "PetaApp Maintenance Tool", open the terminal window, start the /mnt/floppy/
pahostid in the floppy, sequential No. of 8 digits is heard and enter them.
Important: [Sequential No.] for HOST ID generation of "1" + "Serial No. (7 digits)".
Example) Serial No.: 1001081 → Sequential No.: 11001081
Floppy disk mounting procedure
Insert the floppy disk into the FD drive of the PC server. Right-click on the desktop and show
the pop-up menu. Select "floppy" from "Discs...". A floppy icon appears on the desktop, and
the floppy disk is mounted.
Operating Terminal Window
Right-click anywhere (except icons) on the desktop. Click "New Terminal" to open the terminal
window. Type "exit" to close it.
6.
Enter the "hostid" command in the terminal window and check the registered HOST ID.
Do not forget the registered HOST ID, since the PetaApp control software is licensed to this
HOST ID.
7.
Restart after having unmounted and ejected the CD-ROM (and the floppy disk if mounted).
Floppy disk unmounting procedure
Right-click the floppy icon on the desktop, and select "Eject" from the popup menu.
Press the Eject button on the FD drive of the PC server to eject the floppy disk.
8.
Enter "setup" in the terminal window and select "Firewall setup".
Check "[*] No firewall" or "(*) Disabled" and click the OK button.
9.
Exit the setup by pressing the Quit button.