Avaya DEFINITY ONE Installation And Upgrades page 330

Internet protocol communications server
Hide thumbs Also See for DEFINITY ONE:
Table of Contents

Advertisement

Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10 555-233-109
6
Hardware Additions
Downloading Firmware to Port Circuit Packs
Check SPE
1. Log into DEFINITY ONE or IP600.
2. Type status system all-cabinets and press
Locate Target Boards
If you do not know the target board locations, locate DS1 target boards, type list
configuration ds1 and press
note the board location. You will need it later in the process. Or, To locate other
target boards, type list configuration all and press
Verify Trunk Status (optional)
This optional procedure for DS1 target boards allows you to see which ports are in
service.
1. Type list configuration board UUCSS and press
associated with a particular DS1 board. Note the total number of ports.
2. Type display port UUCSSpp , where pp is the port number of one of the
ports, and press
3. Type status trunk n , where n is the trunk group number, and press
Note the status of all the ports in service for that particular DS1 board.
4. If the number of ports in the group does not equal the total number of ports,
repeat step 2 for a port number not listed.
For example, if trunk group 6 shows only ports 01 through 15, then display
port 17 to identify the trunk group number for the rest of the ports for that
particular DS1 board. Note the status of all the ports in service in that trunk
group.
. Look for the "P" suffix in the Code column and
Enter
to find the trunk group number.
Enter
December 2001
.
Enter
.
Enter
to identify the ports
Enter
Issue 6
6-14
.