Avaya DEFINITY ONE Installation And Upgrades page 132

Internet protocol communications server
Hide thumbs Also See for DEFINITY ONE:
Table of Contents

Advertisement

Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10 555-233-109
1
Install and Cable the Cabinet
Install equipment room hardware for DEFINITY ONE
Each column of sneak fuse panels requires approximately 8 inches (20 cm) of
horizontal wall space. Connector cables connect the network interface to the
sneak fuse panel. Also, use 157B connecting blocks equipped with SCP-110
protectors for sneak current protection.
NOTE:
Sneak current protectors with a rating of 350 mA at 600 V must be UL listed
for United States installations and Canadian Safety Association
certified for Canadian installations. The panel contains 2 25-pair connectors,
fuse removal tool, and fifty 220029 Sneak Fuses (and 2 spares). Use the
SCP-110 protectors with 110-type hardware and on the 507B sneak fuse
panel. The SCP-110 protectors can be ordered separately and installed on
the 157B connecting block. Fifty protectors are required per block.
1. Install the 507B near the network interface or MDF with locally-obtained
#12 x 3/4-inch screws (or equivalent).
Issue 6
December 2001
1-92
CSA)
(

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip600