Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10 555-233-109
1
Install and Cable the Cabinet
Check AC power and ground for DEFINITY ONE
B
A
cadmgrd1 KLC 042399
Figure Notes
1. 6 AWG (#40) (16 mm
ground wire
2. 6 AWG (#40) (16 mm
wire to next cabinet
3. Single-point ground block
Figure 1-34. Typical two-cabinet CMC grounding
1
1
3
1
2
2
) cabinet
4. AC load center single-point ground
5. 10 AWG (#25) (6 mm
2
) ground
coupled bonding conductor (CBC)
6. 6 AWG (#40) (16 mm
from single-point ground block to the
AC load center single-point ground
Issue 6
December 2001
1-70
6
4
5
2
) wire to
2
) ground wire