Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10 555-233-109
1
Install and Cable the Cabinet
Install emergency transfer panel and associated telephones
3. Locate the circuit start selection switches (the first 10 two-position switches
on the left side of the 808A. See
switches set each of the 5 incoming trunk lines to either loop start or
ground start. Two switches are used for each of the 5 circuits; switches 1
and 2 are used for circuit 1, switches 3 and 4 are used for circuit 2, and so
forth. See
Table 1-23. Trunk/test switches
Switch number
1
2
3
4
5
6
7
8
9
10
11
12
4. Connect a 25-pair cable between the male RJ21 25-pair connector on the
808A and the yellow field on the MDF.
pinouts.
5. Make cross-connections for each emergency trunk/emergency station pair.
See
6. On the trunk identification label at the bottom of the panel, record the trunk
line, extension, and location for each circuit.
7. To each voice terminal designated as an emergency terminal, attach a
label identifying it as such. The labels are provided with the unit.
8. Check the system for normal operation as follows:
Table
1-23.
Circuit number
1
1
2
2
3
3
4
4
5
5
Not Used
Test Switch
Figure 1-65 on page 1-130
a. Place the test switch (switch 12) in NORMAL OPERATION.
b. Ensure the power supply is providing -48 VDC at 80 mA maximum.
The power LED should be ON.
c. Check wiring connections.
Figure 1-64 on page
Table 1-24 on page 1-128
and
Figure 1-66 on page
Issue 6
December 2001
1-127
1-126.) These
shows the
1-131.