Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10 555-233-109
6
Hardware Additions
Add ISDN-PRI
Add ISDN-PRI
T1 (North American Standard)
This procedure describes adding a T1 line.
1. Use a TN767F or TN767E (or later version) circuit pack to set up an ISDN
PRI trunk. Ensure that the dip switch on the board is set for 24 channels. If
you are using Facility Associated Signaling (FAS), 23 channels are
available to be used as trunk group members. Channel 24 must be used to
create a signaling group for the trunk groups. If you are using Non Facility
Associated Signaling (NFAS), it is possible, in some instances, to use all 24
channels for trunk group members.
2. To create a PRI trunk:
E1 (International Standard)
1. Use a TN464F circuit pack. Ensure that the dip switch on the board is set
for 30 channels (E-1). If you are using Facility Associated Signaling (FAS),
29 channels are available to be used as trunk group members. Channel 16
must be used to create a signaling group for the trunk groups. If you are
using Non Facility Associated Signaling (NFAS), it is possible to use all 30
channels for trunk group members in some instances.
2. To create a trunk group, do the following:
a. Enter ADD DS1 (board location) at the SAT terminal session.
b. Enter the required information on the DS1 form.
c. Create a signaling group using the ADD SIG NEXT command. If you
are using FAS signaling, use the 24th channel on your DS1 board as
the D-channel for your signaling group. If you are using NFAS
signaling, enter N in the associated signaling field. List the trunk
board location in the Trunk Board field.
d. Create a trunk group by using the ADD TRUNK NEXT command:
1. Complete the required information on the Trunk Group form
pages.
2. Enter the port locations of the trunk members on the Trunk
Group Member page.
3. Enter the correct signaling group number.
a. Determine the slot assignment of the circuit packs to be added.
b. Install the DS1 interface circuit pack in the assigned carrier slot.
c. Enter ADD DS1 (board location) at the SAT terminal session.
d. Enter the required information on the DS1 form.
Issue 6
December 2001
6-27