Install and Cable the Cabinet
Install and wire telephones and other equipment
Local and phantom power
The Attendant Console's (AC) maximum distance from the system is limited.
See
Table
Table 1-16. Attendant Console cabling distances
Enhanced Attendant Console
(302C1)
With Selector Console
Phantom powered
Locally powered
Without Selector Console
Phantom powered
Locally powered
Auxiliary power
The nonessential functions of an AC and its optional 26A1 or 24A1 selector
console derive power from an auxiliary power source. During short power
outages, provide auxiliary power for an AC through this cable so the console
remains fully operational.
NOTE:
Only 1 console can derive auxiliary power from the system and through the
auxiliary cable located in the trunk/auxiliary field.
A console's maximum distance from its auxiliary power source is:
800 feet (244 m) for a 302A1
350 feet (107 m) for a 301B1 and 302C1
An AC can also derive auxiliary power from:
Individual 1151A or 1151A2 power supply
MSP-1 power supply
258A-type adapters
Bulk power supplies such as the 1145A1
1-16.
24 AWG Wire (0.26 mm
Feet
800
5000
1400
5000
2
)
26 AWG Wire (0.14 mm
Meters
Feet
244
500
1524
3400
427
900
1524
3400
Issue 6
December 2001
1-108
2
)
Meters
152
1037
274