Install and Cable the Cabinet
Install emergency transfer panel and associated telephones
Install telephone for power transfer unit
Follow the appropriate procedure for your installation.
Trunk/auxiliary field: telephone used only for emergency transfer
1. Connect a pair of wires between the -48V and GRD terminals on the yellow
emergency transfer row/connecting block and the EM TRANS RELAY
PWR terminal. See
2. Connect CO trunk leads from the purple field to the TC terminals on the
yellow emergency transfer row/connecting block for each trunk.
3. Connect CO trunk leads from the green field to the TK terminals on the
yellow emergency transfer row/connecting block for each trunk.
4. Connect the ST leads on the yellow emergency transfer row/connecting
block for each emergency transfer telephone to the ST terminal
appearance in the yellow trunk/auxiliary field. The ST terminal leads should
be terminated on the following pairs: 1, 4, 7, 10, 13, 16, 19, or 22 (the first
pair of any 3-pair group).
5. Connect the ST leads from the terminal in Step
in the blue or white station distribution field.
Trunk/auxiliary field: telephone used for emergency transfer and as normal
extension
1. Connect a pair of wires between the -48V and GRD terminals on the yellow
emergency transfer row/connecting block to the EM TRANS RELAY PWR
terminal.
2. Connect CO trunk leads from the purple field to the TC terminals on the
yellow emergency transfer row/connecting block for each trunk.
3. Connect CO trunk leads from the green field to the TK terminals on the
yellow emergency transfer row/connecting block for each trunk.
4. Connect telephone leads from the purple analog line board row/ connecting
block to the LC terminals on the yellow emergency transfer row/connecting
block for each telephone.
5. Connect ST leads on the yellow emergency transfer row/connecting block
for each emergency transfer telephone to the ST terminal appearance in
the purple trunk/auxiliary field.
6. Connect the ST leads from the terminal in Step
in the blue or white station distribution field.
Telephone installation
1. Connect the telephone to the information outlet.
2. Install patch cords/jumper wires between the system side and the station
side of the station distribution field on the MDF.
Figure 1-65 on page
December 2001
1-130.
4
to the assigned terminal
5
to the assigned terminal
Issue 6