Avaya DEFINITY ONE Installation And Upgrades page 156

Internet protocol communications server
Hide thumbs Also See for DEFINITY ONE:
Table of Contents

Advertisement

Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10 555-233-109
1
Install and Cable the Cabinet
Install the BRI terminating resistor
Figure 1-58
TN556 BRI switch port is terminated to bottom row C.
T
4
Figure Notes
1. Part of terminating resistor block
2. White or purple field
3. Part of 4-pair blue field
4. From ISDN T-interface circuit
(2-pair)
5. To ISDN S/T-interface terminals
6. 2-pair cross-connect
Figure 1-58. Typical installation of terminating resistor block
For point-to-point wiring, the top row connects to the blue station field. The pair
connects from the 110RA1-12 to the standard 4-pair circuit. Pair 1 from the
110RA1-12 connects to Pair 1 of the station field, and Pair 2 connects to Pair 3 of
the station field.
Connect row B (output) to the second terminal common to the multi-point circuit to
accommodate 2 terminal basic multi-point applications.
shows the wiring connections for the 110RA1-12 terminal block. The
6
2
R
T1
R1
1
9
10
11
7
7. Basic multi-point option
8. 4-pair horizontal cables
9. Row "A"
10. Row "B"
11. Row "C"
December 2001
6
3
8
5
term_blk RPY 012098