Apply liquid sealant to the wire grommet seating surface,
and install the wire grommet into the groove.
Install the wire guide and ignition pulse generator.
Apply a locking agent to the three bolt threads.
Install the bolts and tighten it to the specified torque.
TORQUE: 10 N·m (1.0 kgf·m, 7.3 lbf·ft)
FLANGE BOLTS
GROMMET
GUIDE
ALTERNATOR
IGNITION
PULSE
GENERATOR
10-17