*NO RESPONSE FROM INSTRUMENT CLUSTER —
TEST
4
Note: Ensure there is PCI Bus communication with other modules on the
vehicle before proceeding. If not, refer to the symptom list from the menu
and repair as necessary.
Disconnect the Instrument Cluster C1 harness connector.
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
With the DRBIII select Pep Module Tools.
Select lab scope.
Select Live Data.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Set Probe to x10.
Press F2 again when complete.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
circuit in the MIC C1 connector.
Turn the ignition on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?
Yes → Replace the Instrument Cluster in accordance with the service
→ Go To 5
No
5
Turn the ignition off.
Disconnect the Instrument Cluster C1 harness connector.
Disconnect the BCM C1 harness connector.
Measure the resistance of the PCI bus circuit between the MIC C1 connector and the
BCM C1 connector.
Is the resistance below 5.0 ohms?
Yes → Replace the Body Control Module in accordance with the service
→ Repair the PCI Bus circuit for an open.
No
ACTION
information.
Perform BODY VERIFICATION TEST - VER 1.
information.
Perform BODY VERIFICATION TEST - VER 1.
Perform BODY VERIFICATION TEST - VER 1.
151
COMMUNICATION
Continued
APPLICABILITY
All
All