COMMUNICATION
HEAD STATUS RX FAILURE —
TEST
3
Turn the ignition off.
Reinstall the fuse in the Junction Block.
Remove the Body Control Module from the Junction Block.
NOTE: Ensure all of the Junction Block connectors are completely con-
nected before continuing.
Turn the ignition on.
Measure the voltage of the Fused Ignition Switch Output circuit in the Junction
Block Body Control Module connector cavity 5.
Is the voltage above 10.0 volts?
Yes → Replace the Body Control Module in accordance with the service
→ Replace the Junction Block in accordance with the service infor-
No
Continued
ACTION
information.
Perform BODY VERIFICATION TEST - VER 1.
mation.
Perform BODY VERIFICATION TEST - VER 1.
130