P0351-IGNITION COIL #1 CIRCUIT —
P0355-IGNITION COIL #5 CIRCUIT
When Monitored: With battery voltage greater than 11 volts. Engine running. Engine
RPM less than 8160. No coil in dwell during test.
Set Condition: Peak current is not achieved with battery based dwell plus 1.5 msec of
diagnostic offset. It takes less than 3 seconds during cranking or up to 6 seconds while
running to set. One Trip Fault.
P0356-IGNITION COIL #6 CIRCUIT
When Monitored: With battery voltage greater than 11 volts. Engine running. Engine
RPM less than 8160. No coil in dwell during test.
Set Condition: Peak current is not achieved with battery based dwell plus 1.5 msec of
diagnostic offset. It takes less than 3 seconds during cranking or up to 6 seconds while
running to set. One Trip Fault.
GOOD TRIP COUNTER = 0
ASD RELAY OUTPUT CIRCUIT OPEN
CAPACITOR(S) SHORTED TO GROUND
ASD OUTPUT CIRCUIT SHORTED TO GROUND
COIL ON PLUG
COIL CONTROL CIRCUIT SHORTED TO GROUND
COIL CONTROL CIRCUIT OPEN
PCM
TEST
1
Ignition on, engine not running.
With the DRBIII , read DTCs and record the related Freeze Frame data.
Is the Good Trip Counter displayed and equal to zero?
Yes → Go To 2
→ Refer to the INTERMITTENT CONDITION symptom in the
No
POSSIBLE CAUSES
ACTION
Driveability category.
Perform POWERTRAIN VERIFICATION TEST VER - 5 - NGC.