Symptom:
*ALL DOORS FAILING TO UNLOCK FROM ONE SWITCH
DOOR LOCK SWITCH OR DOOR CYLINDER LOCK SWITCH OPERATION
TEST
1
Operate the power door lock switch or the door cylinder lock switch in the unlock
position.
Is a Power Door Lock Switch or a Door Cylinder Lock Switch inoperative in the
unlock position?
Yes → Replace the Power Door Lock Switch or Door Cylinder Lock
→ Test Complete.
No
POSSIBLE CAUSES
ACTION
Switch.
Perform BODY VERIFICATION TEST - VER 1.
POWER DOOR LOCKS/RKE
497
APPLICABILITY
All