Sign In
Upload
Manuals
Brands
Emerson Manuals
Transmitter
Rosemount 3051P
Emerson Rosemount 3051P Manuals
Manuals and User Guides for Emerson Rosemount 3051P. We have
3
Emerson Rosemount 3051P manuals available for free PDF download: Reference Manual, Quick Start Manual
Emerson Rosemount 3051P Reference Manual (110 pages)
In-Line Pressure, with HART Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 6.65 MB
Table of Contents
Table of Contents
3
Using this Manual
11
Models Covered
11
Rosemount 3051P In-Line Gage Pressure Transmitter
11
Rosemount 3051P In-Line Absolute Pressure Transmitter
11
Product Recycling/Disposal
11
2Section 2: Configuration
11
Safety Messages
13
System Readiness
14
Confirm Correct Device Driver
14
HART Installation Flowchart
16
Transmitter Overview
17
Configuration Overview
19
Configuration Basics
19
Configuring on the Bench
19
Configuration Tools
20
Setting the Loop to Manual
21
Verify Configuration
21
Verifying Configuration with Field Communicator
21
Verifying Configuration with AMS Device Manager
22
Verifying Configuration with Local Operator Interface
22
Verifying Process Variables Configuration
22
Basic Setup of the Transmitter
22
Setting Pressure Units
22
Rerange the Transmitter
23
Damping
26
Configuring the LCD Display
27
Detailed Transmitter Setup
27
Configuring Alarm and Saturation Levels
27
Configuring Scaled Variable
29
Re-Mapping Device Variables
30
Performing Transmitter Tests
31
Verifying Alarm Level
31
Performing an Analog Loop Test
31
Simulate Device Variables
32
Configuring Burst Mode
33
Establishing Multidrop Communication
34
Changing a Transmitter Address
35
Communicating with a Multidropped Transmitter
35
Overview
37
Safety Messages
37
Considerations
38
Installation Considerations
38
Environmental Considerations
39
Mechanical Considerations
39
Installation Procedures
39
Mount the Transmitter
39
Impulse Piping
41
Inline Process Connection
43
Rosemount 306 Manifold
44
Rosemount 306 Integral Manifold Installation Procedure
44
Overview
45
Safety Messages
45
Local Operating Interface (LOI)/LCD Display
46
Rotating LCD/LOI Display
46
Configuring Transmitter Security
46
Setting Security Switch
47
HART Lock
47
Configuration Button Lock
48
LOI Password
48
Setting Transmitter Alarm
49
Electrical Considerations
49
Conduit Installation
50
Power Supply
50
Wiring the Transmitter
51
Grounding the Transmitter
52
Transient Protection Terminal Block Grounding
53
Overview
55
Safety Messages
55
Recommended Calibration Tasks
56
Field Installation Tasks
56
Bench Calibration Tasks
56
Calibration Overview
56
Determining Necessary Sensor Trims
57
Determining Calibration Frequency
58
Trim the Pressure Signal
58
Sensor Trim Overview
58
Perform a Sensor Trim
59
Recall Factory Trim-Sensor Trim
61
Trim the Analog Output
61
Performing Digital-To-Analog Trim (4-20Ma Output Trim)
62
Performing Digital-To-Analog Trim (4-20Ma Output Trim) Using Other Scale
63
Recalling Factory Trim-Analog Output
63
Switching HART Revision
64
Switching HART Revision with Generic Menu
64
Switching HART Revision with Field Communicator
64
Switching HART Revision with AMS Device Manager
65
Switching HART Revision with LOI
65
Overview
67
Safety Messages
67
Diagnostic Messages
69
Disassembly Procedures
71
Removing from Service
71
Removing Terminal Block
72
Removing the LOI or LCD Display
72
Reassembly Procedures
72
Installing LOI/LCD Display
72
Service Support
73
Safety Instrumented Systems (SIS) Certification
75
Rosemount 3051P Safety Certified Identification
75
Installation in SIS Applications
75
Configuring in SIS Applications
75
Rosemount 3051P SIS Operation and Mainenance
76
Inspection
78
Performance Specifications
79
Reference Accuracy
79
Long Term Stability
79
Dynamic Performance
79
A.1 Performance Specifications
79
Ambient Temperature Effects Per 50 °F (28 °C)
80
Mounting Position Effects
80
Vibration Effect
80
Power Supply Effect
80
Electromagnetic Compatibility (EMC)
80
Transient Protection (Option Code T1)
80
Functional Specifications
80
Service
80
Power Supply
80
Load Limitations
80
Overpressure Limits
81
Burst Pressure Limit
81
Failure Mode Alarm
81
Temperature Limits
81
Humidity Limits
81
Turn-On Time
81
Volumetric Displacement
82
Damping
82
Physical Specifications
82
Electrical Connections
82
Process Connections
82
Process-Wetted Parts
82
Process Isolating Diaphragms
82
Non-Wetted Parts
82
Shipping Weights
82
A.3 Physical Specifications
82
Dimensional Drawings
83
A.5 Ordering Information
84
Ordering Information
84
Options
89
Standard Configuration
89
Custom Configuration
89
Tagging (3 Options Available)
89
Optional Rosemount 306 Integral Manifolds
89
Other Seals
89
Output Information
89
Display and Interface Options
89
A.6 Options
89
Configuration Buttons
90
Bracket Options
90
A.6.8 Configuration Buttons
90
European Directive Information
91
North America
91
Europe
91
B.4 International
93
International
93
Technical Regulations Customs Union (EAC)
94
C Ombinations
94
Conduit Plugs and Adapters
94
B.8 Installation Drawings
95
Installation Drawings
95
Menu Trees
99
Fast Keys
101
LOI Menu Tree
103
D.1 LOI Menu Tree
105
Number Entry
105
LOI Menu Tree - Extended Menu
106
D.3 Number Entry
107
D.4 Text Entry
108
Text Entry
108
Advertisement
Emerson Rosemount 3051P Reference Manual (110 pages)
In-Line Pressure Transmitter with HART Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 4.96 MB
Table of Contents
Table of Contents
3
Chapter 1 Introduction
5
Using this Manual
5
Models Covered
5
Product Recycling/Disposal
5
Chapter 2 Configuration
7
Safety Messages
7
System Readiness
8
HART ® Installation Flowchart
10
Transmitter Overview
11
Damping
13
Configuration Overview
14
Configuration Basics
14
Verifying Configuration
17
Primary Variable 2, 2, 5, 1
18
Range Values
18
Tag
18
Transfer Function 2, 2, 1, 1
18
Basic Setup of the Transmitter
19
Configuring the LCD Display
24
Pressure Units
24
Display Configuration
24
Detailed Transmitter Setup
25
Performing Transmitter Tests
30
Configuring Burst Mode
32
Establishing Multidrop Communication
34
Chapter 3 Hardware Installation
37
Overview
37
Safety Messages
37
Considerations
38
Installation Procedures
39
Rosemount 306 Manifold
48
Chapter 4 Electrical Installation
49
Overview
49
Safety Messages
49
Local Operating Interface (LOI)/LCD Display
50
Configuring Transmitter Security
52
Local Operator Interface (LOI) Password
52
Set Transmitter Alarm
55
Electrical Considerations
55
Operation and Maintenance
63
Overview
63
Safety Messages
63
Recommended Calibration Tasks
64
Calibration Overview
65
Trimming the Pressure Signal
68
Lower Sensor Trim
69
Upper Sensor Trim
70
Trimming the Analog Output
72
Switching HART ® Revision
75
Chapter 6 Troubleshooting
77
Overview
77
Safety Messages
77
Troubleshooting for 4-20 Ma Output
78
Diagnostic Messages
80
Disassembly Procedures
86
Reassembly Procedures
88
Service Support
88
Safety Instrumented Systems Requirements
91
Safety Instrumented Systems (SIS) Certification
91
Safety Certified Identification
91
Installation in Safety Instrumented Systems (SIS) Applications
91
Configuring in Safety Instrumented Systems (SIS) Applications
92
Safety Instrumented Systems (SIS) Operation and Maintenance
93
Inspection
95
Appendix A Reference Data
97
Product Certifications and Installation Drawings
97
Ordering Information, Specifications, and Dimensional Drawings
97
Appendix B Field Communicator Menu Trees and Fast Keys
99
Menu Trees
99
Fast Keys
103
Appendix C Local Operator Interface (LOI)
105
Local Operator Interface (LOI) Menu Tree
105
Local Operator Interface (LOI) Menu Tree - Extended Menu
106
Entering Numbers
107
Entering Text
108
Emerson Rosemount 3051P Quick Start Manual (44 pages)
Pressure Transmitter with 4-20 mA HART Protocol (Revision 5 and 7)
Brand:
Emerson
| Category:
Transmitter
| Size: 7.77 MB
Table of Contents
Table of Contents
2
About this Guide
3
System Readiness
4
Mount the Transmitter
6
Set the Switches
10
Connect the Wiring and Power up
11
Verify Transmitter Configuration
14
Trim the Transmitter
20
Safety Instrumented Systems
23
Product Certifications
24
Advertisement
Advertisement
Related Products
Emerson Rosemount 3051S Series
Emerson Rosemount 3051
Emerson Rosemount 3051N
Emerson Rosemount MultiVariable 3051SMV
Emerson Rosemount MultiVariable 3051SFA
Emerson Rosemount MultiVariable 3051SFP
Emerson Rosemount 3051D
Emerson Rosemount 3051SFx
Emerson Rosemount 3051HT
Emerson Rosemount 3051L
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL