Setting the Zero Reset

■Type
Set how zero reset is to be executed.
Setting [Display]
Real value [REAL]
(Default value)
Hold value [HOLD]
Sets the measured value when a zero reset is executed to zero.
Sensor head
Measurement of height
from reference surface
Reference A
Zero reset
Sets the measured value (hold value) when a zero reset is executed
to zero. This setting is enabled when hold measurement is performed.
Sensor head
Hold A
(reference)
Zero reset
Setting the Output Conditions
Description
Measurement of height
from reference surface
Direction of movement
Chapter 3
ZW
3-37
User's Manual