Omron ZW Series User Manual page 215

Displacement sensor, confocal fiber type
Hide thumbs Also See for ZW Series:
Table of Contents

Advertisement

Item
External
52-pole
Bank
interface
extension
connector
Main
Exposure time
functions
Measuring cycle
Material setting
Measurement Item
Filtering
Outputs
Display
Number of configurable banks
Task process
System
Ratings
Power supply voltage
Current consumption
Insulation resistance
Dialectic strength
Environme
Degree of protection
ntal
immunity
Vibration resistance (destructive)
Shock resistance (destructive)
Ambient temperature
Ambient humidity
Grounding
Materials
Weight
Accessories
ZW-C10T
Selected
Transistor output system
bank output
Output voltage: 21.6 to 30 VDC
(BANK_OUT
Load current: 50 mA or less
1 - 3)
Residual voltage when turning ON: 1.2 V or less
Leakage voltage when turning OFF: 0.1 mA or less
Selected
DC input system
bank input
Input voltage: 24 VDC ±10 % (21.6 to 26.4 VDC)
(BANK_SEL
Input current: 7 mA Typ. (24 VDC)
1 -3)
Voltage/Current when turning ON: 19 V/3 mA or more
Voltage/Current when turning OFF: 5 V/1 mA or less
Auto/Manual
500 Pm to 10 ms
Standard/Mirror/Diffusion surfaces
Height/Thickness/Calculation
Median/Average/Differentiation/High pass/Low pass/Band
pass
Scaling/Different holds/Zero reset/Logging for a measured
value
Measured value/Threshold value/Analog output voltage or
current value/Judgment result/Resolution/Exposure time
Max. 8 banks
Multi-task (up to 4 tasks per bank)
Save/Initialization/Display measurement information/
Communication settings/Sensor Head calibration/Key-lock/
Trigger-key input
21.6 V to 26.4 VDC (including ripple)
500 mA max.
Across all lead wires and controller case: 20 M: (by 250 V
megger)
Across all lead wires and controller case: 1,000 VAC, 50/60
Hz, 1 min
IP20 (IEC60529)
10 to 55 Hz, 0.35-mm single amplitude, 50 min each in X, Y,
and Z directions
150 m/s
2,
3 times each in six directions (up/down, left/right,
forward/backward)
Operating: 0 to +40 °C
Storage: -15 to +60 °C (with no icing or condensation)
Operating and storage: 35 % to 85 % (with no condensation)
D-type grounding (Grounding resistance of 100 : or less)
Note: For conventional Class D grounding
Case: PC
Approx. 750 g (main unit only)
Instruction
sheet,
Member
registration
sheet
Specifications
ZW-C10AT
ZW-C15T
Instruction
Instruction
sheet,
sheet,
Member
Member
registration
registration
sheet and
sheet
software for
setting (CD-
ROM)
Chapter 6
Controller
ZW-C15AT
Instruction
sheet,
Member
registration
sheet and
software for
setting (CD-
ROM)
ZW
6-9
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zw-s20Zw-s40

Table of Contents