Using The Zero Reset Function - Omron ZX-T Operation Manual

Zx-t series smart sensors
Hide thumbs Also See for ZX-T:
Table of Contents

Advertisement

Section 5
DETAILED SETTINGS

Using the Zero Reset Function

When the zero reset function is used, the reference value "0" is registered as the height and
the measured value can be displayed and output as a positive or negative deviation
(tolerance) from the reference value.
In RUN mode, the measured value can be reset to 0 at any timing during measurement.
Example 1: Using the Height of the Sensing Object as the Reference Value and the
Example 2: Measuring Height Differences on Sensing Objects (Zero Reset at Each
When resetting to zero for each measurement, change the settings so the zero reset level is not
saved.
You can set any offset value when you want to set a non-zero measured value.
ZX-T
92
Operation Manual
Tolerance Output as the Measured Value
Sensing
Sensing
Reference value
object
object
Measurement)
Measures
this step.
Zero reset
Operation
p. 96
−0.2 (LOW threshold)
+0.2 (HIGH threshold)
Zero reset
Zero reset

Advertisement

Table of Contents
loading

Table of Contents