Settings For Processing When Measurement Cannot Be Performed - Omron ZW Series User Manual

Displacement sensor, confocal fiber type
Hide thumbs Also See for ZW Series:
Table of Contents

Advertisement

Chapter 4
Settings for I/O

Settings for Processing when Measurement Cannot be Performed

Set the output methods for linear, judge, and terminal block when a non-measurement
state occurs temporarily due to insufficient received light amount or the reset input state,
for example.
Example: When the waveform skips due to insufficient received light amount cycle
Setting [Display]
Keep [KEEP]
Clamp [CLAMP]
(Default value)
In hold measurement, the output before the first hold value is obtained will be the same as [Clamp] even
if [Keep] is set.
ZW
4-28
User's Manual
Amount of displacement
Direction of
workpiece
When [Keep] is selected
movement
Amount of displacement
Analog output/Binary output
The status immediately before measurement is stopped is held and output.
Outputs the set Clamp value (abnormal
value).
State with waveform skip caused
by insufficient light amount
As the value before the skip occurred is kept,
this is effective in canceling waveform skip.
Outputs
Judgment Output
All OFF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zw-s20Zw-s40

Table of Contents