Omron ZW Series User Manual page 65

Displacement sensor, confocal fiber type
Hide thumbs Also See for ZW Series:
Table of Contents

Advertisement

■ Bank data
ZW series can hold up to eight sets of settings, which are called a "bank (BANK)".
When the device setup is changed, you can switch the bank externally.
● What is bank?
The sensing settings for measurement
Sensing
Filter
Output
I/O
● Example of bank switching for settings
If you register settings of various classes,
Sensing setting for product class A
Sensing
Filter
Output
I/O
I/O
I/O
Measuring operation
with the contents set
in BANK1
• If only the "threshold value" is different in the settings for a bank, by changing the mode of the bank,
you can increase the number of banks from 4 to 32.
Changing the Bank Mode p.3-43
• The output destination (current output value/voltage output value) in the I/O setting parameters is set
the same for all banks. The output destination cannot be set separately for individual banks.
Threshold value
Register the different settings
for changing the device setup.
Threshold value
BANK1
Switch
to BANK2.
BANK2
BANK3
BANK8
Sensing
TASK1
Measurement point
Filter
Threshold value
Output
I/O
Overview of Setting and Measurement
are held as one bank.
Sensing
Filter
Output
I/O
Sensing setting for product class B
Sensing
Filter
I/O
Output
I/O
I/O
It is easy to change the device setup.
TASK4
TASK1 to TASK4 are
Measurement point
Filter
specified in the settings
for each bank.
Threshold value
Output
BANK1
Chapter 2
Threshold value
BANK
Measuring operation
with the contents set in
BANK2
Threshold value
BANK1
BANK2
BANK3
BANK8
ZW
User's Manual
2-7