Omron ZW Series User Manual page 148

Displacement sensor, confocal fiber type
Hide thumbs Also See for ZW Series:
Table of Contents

Advertisement

Chapter 4
Settings for I/O
Setting [Display]
Timer [TIMER]
Off [OFF]
(Default value)
Off delay
[OFF.DLY]
On delay
[ONDLY]
1 shot [1SHOT] When the judgment result
ZW
4-20
User's Manual
Set the timing for judgment outputs to match the operation of external devices.
Outputs the judgment as
soon as the judgment result
has been applied.
After the measurement result
has been applied, delays
turning OFF the PASS output
for the time set to the timer.
Timer time setting range:
1 to 5000 ms
(default value: 1)
After the measurement result
has been applied, delays
turning ON the PASS output
for the time set to the timer.
Also delays turning OFF the
HIGH and LOW outputs for
the timer time.
Timer time setting range:
1 to 5000 ms
(default value: 1)
changes to PASS, outputs
the PASS output for the time
set to the timer.
Neither the HIGH nor the
LOW output is output.
Timer time setting range:
1 to 5000 ms
(default value: 1)
Description
Measured value
HIGH threshold
value
LOW threshold
value
ON
HIGH output
OFF
ON
PASS output
OFF
ON
LOW output
OFF
Measured value
HIGH threshold
value
LOW threshold
value
ON
HIGH output
OFF
ON
PASS output
OFF
ON
LOW output
OFF
Measured value
HIGH threshold
value
LOW threshold
value
ON
HIGH output
OFF
ON
PASS output
OFF
ON
LOW output
OFF
Measured value
HIGH threshold
value
LOW threshold
value
ON
HIGH output
OFF
ON
PASS output
OFF
ON
LOW output
OFF
: Timer time
: Timer time
: Timer time